Main characteristics
• Double configurable input for
strain gauge / potentiometer /
linear signal / TC / RTD
• Two auxiliary analog inputs
• Differential measurement
• High precision: 0.1 % f.s. ±1 digit
• High tripping speed
• Automatic calibration for 6-wire
strain gauge
• Transmitter power supply and
strain gauge probe power supply
• Memory: min. peak, max. peak,
max. peak – min. peak
• 3 configurable alarms, failsafe function
• 2 digital inputs
• up to 4 relay/logic outputs
• 5-digit display
• Serial communication interface:
- RS485/RS232 MODBUS RTU
protocol (optional)
- Profibus DP slave (optional)
• Isolated analog retransmission output
(optional)
Main applications
• Extrusion lines and injection
presses for plastics
• Filling machines
• Food processing plants
• Pressure measurement and trip
points (direct/differential)
• Position measurement and trip
points
• Variable setpoints in fast
processes and automations in
general, with signal
retransmission
Order-no.: F32.204
Manufacturer: GEFRAN
SAGATRON-no.: F32.204
OPERATOR INTERFACE
Display
Configurable from -19999 to 99999 xith
settable decimal point
5 digits bicolors (R/V) 13mm
2 digits (V) 7mm
LED signals: n.14 red
Keys: n.6
ANALOG INPUTS
Accuracy: 0,1% f.s. ± 1 digit
(0,2% for TC)
Min. sampling time:
2 msec for main inputs
10msec for auxiliary inputs
Resolution:
• without filter: 100000 steps@2msec
• with digital filter (selectable):
100000 steps@20msec
100000 steps@100msec (50Hz)
Custom linearization:
• fixed intervals: 64 sections
• variable intervals: 32 sections max.
• self-learning
INPUT 1, INPUT 2 main inputs
Strain-gauge: 350Ω
Sensitivity 1,5...4mV/V
Jumper power supply: 5/10Vdc 200mA
Potentiometer:
≥100Ω, Ri > 10MΩ @ 2,5Vdc
Linear DC:
±50mV ... ±10V, Ri > 1MΩ
0/4...20mA, Ri = 50Ω
TC - thermocouple:
J 0...1000°C / 32...1832°F
K 0...1300°C / 32...2372°F
R 0...1750°C / 32...3182°F
S 0...1750°C / 32...3182°F
T -200...400°C / -328...752°F
custom -1999...9999
RTD: 2-3 wires
PT100 -200...850°C / -328...1562°F
int./ext. cold junction compensation
INPUT 3 (auxiliary)
Linear DC:
0...10V, 0/4...20mA, Ri = 50Ω
INPUT 4 (auxiliary)
Linear DC:
0...10V, 0/4...20mA, Ri = 50Ω
ALLARMI
Relay: 5A/250Vac cosϕ=1
Logic: 24Vdc source/sink
OUTPUT 1
Relay (NO/NC)* or Logic
(according to model)
OUTPUT 2
Relay (NO/NC)* or Logic
(according to model)
OUTPUT 3**
Relay (NO/NC)* or Logic
(according to model)
OUTPUT 4**
Relay (NO/NC)* or Logic
(according to model)
* terminal “C” in common
** alternate: version only with OUTPUT3
(switching contact) and interface for MD8
expansion unit
• The relay can be energized or de-energized
in alarm state (selection via keyboard).
• The outputs can be assigned to alarm
setpoints directly or via logic functions
(AND, OR).
• The outputs can be delayed or assigned
to a hysteresis value (selectable in engineering
units).
• 4 (10) alarm setpoints settable in absolute
value, with functions configurable via
keyboard (direct, reverse, deviation, symmetrical
deviation).
• Setpoint can be set over the entire
selected scale.
• Minimum or maximum setpoint with
latch.
• Setpoint can be excluded in power-up
phase until the input variable has exceeded
the set limit.
A subsequent drop below such limit causes
the relay to trip
ANALOG OUTPUT (optional)
Not available with option of Profibus communication
Isolated 1500V
0/4...20mA, max 500Ω
± 10V, min 500Ω
resolution higher than 0,03%
Configurable via software
COMMUNICATION (optional)
SERIAL INTERFACE:
RS485 2/4 wires optically isolated
Protocol: MODBUS RTU
Profibus DP slave
Protocoll: Profibus DP VO (slave)
CONFIGURATION VIA PC:
TTL service interface, connectable to PC
via “Winstrum” kit
CONNECTIONS
Screw connections
POWER SUPPLY
100...240Vac/dc ±10%,
20...27Vac/dc ±10%,
50...60Hz; max 20VA
Protection via internal fuse, not replaceable
by operator
PROBE POWER SUPPLY
5/10Vdc - 200mA, 2,5Vdc for potentiometers
TRANSMITTER POWER SUPPLY
24Vdc, ±5% - 100mA
AMBIENT CONDITIONS
Work temperature: 0...50°C
Storage temperature: -20...70°C
Humidity: 20...85% Ur non-condensing
WEIGHT
450g
DIMENSION
96 X 48 X 167 mm
ACCESSORIES
MD8 - EXPANSION UNIT
replaces outputs 3 and 4 with an additional
8 outputs (relay or logic, according to
model)
FRONT COVERS
standard Gefran (see catalog)
WINSTRUM KIT
TTL/RS232 interface wires + CD
Output |
Special function |
Serial interface |
Power supply |
Type |
Code |
4 Relay |
Transmitter supply selectable |
--- |
20..27Vac/Vdc |
2400-0-0-4R-0-0 |
F32.204 |
4 Relay |
Transmitter supply selectable |
--- |
100..240Vac/Vdc |
2400-0-0-4R-0-1 |
F28.431 |
4 Relay
+ Analog |
Transmitter supply selectable |
--- |
20..27Vac/Vdc |
2400-0-W-4R-0-0 |
F35.857 |
4 Relay
+ Analog |
Transmitter supply selectable |
--- |
100..240Vac/Vdc |
2400-0-W-4R-0-1 |
F28.816 |
4 Relay |
Transmitter supply selectable |
RS485 Modbus |
20..27Vac/Vdc |
2400-0-0-4R-2-0 |
F35.475 |
4 Relay |
Transmitter supply selectable |
RS485 Modbus |
100..240Vac/Vdc |
2400-0-0-4R-2-1 |
F30.659 |
4 Relay |
Transmitter supply selectable |
PROFIBUS DP |
20..27Vac/Vdc |
2400-0-0-4R-P-0 |
F39.775 |
4 Relay |
Transmitter supply selectable |
PROFIBUS DP |
100..240Vac/Vdc |
2400-0-0-4R-P-1 |
F41.522 |
4 Relay |
Transmitter supply selectable |
RS485 Modbus |
20..27Vac/Vdc |
2400-1-0-4R-2-0 |
F39.405 |
4 Relay |
Transmitter supply selectable |
RS485 Modbus |
100..240Vac/Vdc |
2400-1-0-4R-2-1 |
F31.317 |
4 Relay |
Transmitter supply selectable |
PROFIBUS DP |
20..27Vac/Vdc |
2400-1-0-4R-P-0 |
F35.048 |